On this page

Your LG has one evaporator, and it sits behind the freezer wall. The freezer stays cold because it is right next to that cold source. The fresh food compartment gets nothing of its own. It only gets air pushed up a cold air duct by the evaporator fan and let in by a damper. Ice over the coils, a dead fan, or a stuck damper cuts that path, so the freezer holds while the fridge warms.

The freezer sits on the branch with no moving parts in it, which is why it keeps working while the fridge goes warm.

Your LG has one evaporator, and it sits behind the freezer wall. The freezer stays cold because it is right next to that cold source. The fresh food compartment gets nothing of its own. It only gets air pushed up a cold air duct by the evaporator fan and let in by a damper. Ice over the coils, a dead fan, or a stuck damper cuts that path, so the freezer holds while the fridge warms.

The freezer sits on the branch with no moving parts in it, which is why it keeps working while the fridge goes warm.

LG Refrigerator Error Codes For Cooling Problems

Use this table to match the code on your LG display to the most likely fault and jump to the repair section above.

CodeWhat the code narrows the fault toSection to read
FF, Er FFFreezer evaporator fan motor fault, often frost locking the blade2. Evaporator fan
rF, Er rFRefrigerator fan motor abnormality, often caused by frost buildup2. Evaporator fan
dH, F dH, r dHDefrost ran past an hour, so heater, thermal fuse, ice or board1. Ice buildup
dS, F dS, r dSDefrost sensor shorted or disconnected1. Ice buildup
rS, Er rSRefrigerator sensor shorted or disconnected5. Faulty thermistor
FS, Er FSFreezer sensor shorted or disconnected5. Faulty thermistor
CF, E CFCondenser fan motor at the back bottom of the cabinet9. Condenser coils and fan
CO, C1Communication fault at the control board or the display10. Main control board
67Door held open by a gap or an object inside the cabinet7. Door gasket
OF FDemo mode, which disables cooling in both compartments8. Demo mode

No code at all with a warm fridge and a cold freezer is still useful, since LG logs no damper fault on most models. That points to the damper or blocked vents.

10 Reasons An LG Refrigerator Is Not Cooling But The Freezer Works

These are ordered by how often they turn up on real service calls. Work down the list and stop when the symptom matches yours. If you already swapped a part or have a fault code on the display, jump to the matching section.

1. Ice Buildup Behind The Freezer Wall

Parts involved: Defrost heater, defrost sensor, bi-metal thermal fuse.

Ice forms over the evaporator coils behind the freezer wall and blocks the cold air that should travel up to the fridge. A manual defrost fixes it for a few days and then it returns, which points at a failed defrost heater, bi-metal fuse, or defrost sensor. On LG units, watch for dH, F dH, or Er dH, which LG logs when the unit spends more than an hour trying to defrost, and F dS, which means the freezer defrost sensor is shorted or disconnected.

Solution

  • Unplug the fridge and leave both doors open at least 8 hours to melt ice.
  • Pull the rear panel and test the heater and bi-metal fuse for continuity.
  • Replace the defrost sensor if F dS or Er dS shows on the display panel.
  • A dH code with a healthy sensor points at the heater or the thermal fuse.
  • French Door and InstaView need the ice maker out to reach the rear panel.

2. The Fan That Pushes Cold Air Into The Fridge Has Stopped

Parts involved: Evaporator fan motor, fan blade, wiring harness.

The evaporator fan motor pushes cold air from the freezer into the fridge. If it stops, the freezer still feels cold because it sits next to the evaporator, but the fridge warms up. The giveaway is silence when you press the freezer door switch, and LG flags it as FF when the freezer fan reports a fault. 

Solution

  • Hold the freezer door light switch and listen for the fan spinning up.
  • Press the freezer door switch and listen; if silent, remove the freezer rear panel.
  • Spin the fan blade by hand. If it is seized or noisy, replace the fan motor (e.g., 4681JB1027C or EAU63103201).
  • On French Door and InstaView models, remove the ice maker first; on Side-by-Side models, the fan is behind the freezer rear wall.
  • Test the wire harness for voltage; replace the motor if power is present, but the fan does not spin.
  • Reassemble and confirm the fan runs with the door switch pressed before closing.

3. The Air Flap Between Freezer And Fridge Is Stuck

Parts involved: Damper control assembly, damper motor, air duct cover.

The damper is a motorized flap in the duct between the freezer and the fresh food section. When the motor fails, or the flap ices over, the fridge is sealed off from the cold even while the fan runs normally. Most LG models do not log a damper code, so a warm fridge, a cold freezer, and a clean display point here or at blocked vents.

Solution

  • Unplug the refrigerator and remove the fridge rear panel to access the damper.
  • If the damper is iced over, defrost it with a hair dryer on low heat and dry it thoroughly.
  • Test the damper motor resistance; replace it if the reading is open or shorted.
  • On French Door and InstaView models, verify the control board signal to the damper before replacing it.
  • On Side-by-Side models, check the air duct between compartments for ice or debris.

4. Vents Are Blocked By Food Or A Packed Fridge

Parts involved: Air duct cover, fresh food vents, crisper vents.

Cold air enters through small vents that are easy to block with containers, bags, or overfilled shelves. This is the cheapest and most overlooked cause. LG recommends keeping the fridge about 70% full for proper airflow.

Solution

  • Remove items blocking the rear wall and ceiling vents in both the fridge and freezer.
  • Reorganize food so nothing touches the vents or the rear wall.
  • Keep the refrigerator at or below 70% capacity.
  • Check door bins. Overloaded bins can stop the door from sealing properly.
  • Wait 24 hours after clearing vents before assuming a repair is needed.

5. Faulty Refrigerator Thermistor

Parts involved: Refrigerator thermistor, wiring harness, main control board.

The fresh food thermistor tells the control board how cold the fridge is. If it drifts or fails, the board may think the fridge is cold enough and stop sending cold air. LG often shows rS or FS when this happens. 

Solution

  • Look for an rS code on the display before you pull any interior panel.
  • Measure the thermistor, which reads near 5 kiloohms at room temperature.
  • Replace the sensor on any open or shorted reading, since it just clips in.
  • Inspect the harness at the hinge, since a chafed wire reads the exact same.
  • French Door clips the thermistor near the top right of the fridge liner.

6. Clogged Defrost Drain

Parts involved: Defrost drain tube, drain heater clip, drain pan.

Meltwater from each defrost cycle runs down a drain tube to a pan near the compressor. When the tube clogs with debris or freezes shut, the water backs up and refreezes over the coils and the air path. Ice under the drawers or water on the kitchen floor usually shows up before the fridge warms, and the blocked airflow can then trigger FF or dH.

Solution

  • Pour warm water into the drain hole behind the rear panel until clear.
  • Clear the tube with a turkey baster or a flexible brush, nothing sharp.
  • Confirm the drain heater clip is seated, or the clog will simply come back.
  • Flush with warm water and baking soda to clear slime from the tube and pan.
  • Bottom Freezer and French Door drains sit under the drawer, out of sight.

7. Worn Or Misaligned Door Gasket

Parts involved: Door gasket, flipper mullion, door hinge, leveling feet.

A torn, flattened or dislodged gasket lets room air into the fresh food section all day, so the system runs constantly and the fridge never reaches temperature while the freezer holds. It also loads the evaporator with moisture and brings the frost problem straight back. LG reports a door held open by a gap or an obstruction as code 67, and names door alignment and leveling as a direct cause of frost buildup.

Solution

  • Clean the gasket with warm soapy water and a toothbrush.
  • Press any popped-out section back into the groove on the door.
  • On French Door models, check that the air shield between the doors folds flat when closing.
  • Do the dollar-bill test. If it pulls out easily, replace the gasket.
  • Replace a torn or hardened gasket with the model-specific LG part and allow 24 hours to stabilize.

8. Demo Mode Or Incorrect Temperature Settings

Parts involved: Control panel, display board, temperature settings.

Demo Mode turns off cooling in both compartments for retail display. If the display shows OF F or O FF, nothing will cool properly. Incorrect fridge settings can also make the fridge feel warm while the freezer works.

Solution

  • An OF F reading on the control panel is demo mode, not a system fault.
  • Hold REFRIGERATOR and ICE PLUS together for 5 seconds until you hear the second beep.
  • The panel beeps, and the temperature settings return when demo mode exits.
  • Set the fridge to 37°F (3°C) and the freezer to 0°F (-18°C).
  • Wait 24 hours after changing settings before checking temperatures.

9. Dirty Condenser Coils Or A Failed Condenser Fan

Parts involved: Condenser coils, condenser fan motor, lower grille.

Dirty condenser coils or a failed condenser fan make the compressor overheat and cooling efficiency drop. The fridge section usually warms first. LG recommends cleaning the coils once or twice a year.

Solution

  • Unplug the unit, pull the lower grille, and vacuum the coils and fan blade.
  • Listen near the compressor, since silence there means a stalled condenser fan.
  • Turn the fan blade by hand and replace the motor if it feels stiff or wobbly.
  • Leave two inches of clearance behind the unit and an inch at each side.
  • French Door and Bottom Freezer hide it behind a rear panel at the floor.

10. Main Control Board Failure

Parts involved: Main PCB, display board, relays, wiring harness.

 The main PCB controls cooling, fans, defrost, and damper signals. When it fails, the fridge often warms first because the board stops sending cold-air commands. Multiple intermittent codes or erratic behavior point here.

Solution

  • Check for multiple codes like rS, FS, dS, or FF.
  • Inspect the board for burn marks, swollen capacitors, or corrosion.
  • Test output voltage to the damper and evaporator fan; no voltage means board failure.
  • Replace the main PCB with the model-specific LG part (e.g., EBR41531305, EBR86093714). This is a technician-level repair.

When To Call An Appliance Technician

Call once the problem stops being a part you can see. Sealed system work is not a DIY job, and in California handling refrigerant requires an EPA-certified technician.

  • The freezer is now slipping too, or the compressor is hot and running nonstop.
  • You hear no compressor at all, only a click every few minutes from the start relay.
  • Frost keeps returning within days even after the defrost heater and sensor were replaced.
  • The fault code points at the inverter, the compressor or the sealed system.
  • You have tested the fan and damper and both have power but neither moves, which puts you into board or wiring territory.

Two things worth doing before you book. Check your model and serial with LG, since a number of units built in the mid 2010s carried extended linear compressor coverage and the repair may cost you nothing. And have the model number, the fault code and what you already replaced ready when you call. In San Francisco, a diagnostic visit usually costs more than a thermistor or a damper, so a tech who arrives already knowing what you ruled out saves you a second trip charge.

Frequently Asked Questions

Why is my LG fridge warm but the freezer cold?

Your LG has one evaporator, and it sits behind the freezer wall. The freezer stays cold by proximity. The fridge depends on a fan and a damper to push that air up a duct. Ice on the coils, a dead evaporator fan, or a stuck damper cuts the fridge off while the freezer is unaffected.

Why does my LG fridge only cool after I defrost it?

Because frost is covering the evaporator and blocking airflow. Defrosting clears it for a few days until it builds again. That repeating pattern points at a failed defrost heater, defrost sensor or bimetal fuse. Replace the defrost part; otherwise, you will be unplugging the fridge every week.

Can I keep using the freezer while the fridge side is broken?

Yes, for a short while. The freezer is still below zero, so frozen food stays safe. Move refrigerated items to a cooler or a second fridge. Do not leave it for weeks, because the system is likely running nonstop and that wears the compressor out early.

Is it worth repairing a 10-year-old LG refrigerator?

Usually yes for a fan, damper, thermistor or defrost part, since those repairs are small next to a replacement. That is especially true for a counter-depth or built-in unit sized to a tight San Francisco kitchen. A failed compressor or a sealed system leak at ten years is where replacement starts to win.

Why is my LG freezer not freezing but the fridge is cold?

That reverses the airflow logic, so the evaporator itself is probably not getting cold. Suspect the compressor, the start relay, or a sealed system problem. A damper stuck wide open can also do it by sending too much cold air to the fridge and starving the freezer.

Does an LG refrigerator need refrigerant recharged?

No. It is a sealed system, so refrigerant is never consumed and never needs topping up. If it is low, there is a leak, and that needs an EPA-certified technician to find, repair, and recharge. Anyone offering a quick recharge with no leak repair is selling you a temporary fix.